In addition to the split-and-delay units (SDUs) being an integral part of the permanent instrument endstations CAMP@BL1 and REMI@FL26, FLASH also provides SDUs in the open-port beamlines:
At FLASH2, a grazing incidence SDU is installed, which was developed and built as a BMBF collaborative research (now named "ErUM pro") project of the Universität Münster (H. Zacharias et al.) and DESY. This SDU covers the entire photon energy range of FLASH2, including harmonics, up to 1800 eV and allows X-ray pump–X-ray probe experiments at beamline FL24 as well as soon at the adjacent monochromator beamline FL23. The setup relies on wavefront beam splitting at grazing incidence angles and has a delay range from -5 ps up to 18 ps with sub-femtosecond jitter and resolution.
Reference:
M. Dreimann et al., The soft X-ray and XUV split-and-delay unit at beamlines FL23/24 at FLASH2, J. Synchrotron Rad. 30, 479-489 (2023). Article
Matthias Dreimann , Uni Münster |
|
|